Why monitor carbon dioxide?
Breathing steadily raises indoor CO₂. High CO₂ usually means poor ventilation: people feel tired, dizzy and less focused, and other pollutants may be building up too. A CO2 monitor in classrooms, meeting rooms and offices prompts you to open windows or switches on fresh-air ventilation automatically.
Live CO₂ readings on the display and in the cloud.
Set a threshold and get reminded before reaching 1000 ppm.
Link CO₂ levels to ventilation for better air and lower energy use.
Trends and reports support internal management and inspections.
Indoor air quality standard: CO₂ 1000 ppm (8 hours)
Besides CO₂, Taiwan’s Indoor Air Quality Act sets standards for nine pollutants. The table also shows which ones Gold-Pick monitors measure in real time:
| Pollutant | Standard | Averaging time | Gold-Pick monitors |
|---|---|---|---|
| Carbon dioxide CO₂ | 1000 ppm | 8 hours | Real-time (all models) |
| PM2.5 | 35 μg/m³ | 24 hours | Real-time (MT419) |
| PM10 | 75 μg/m³ | 24 hours | Real-time (MT419) |
| TVOC | 0.56 ppm | 1 hour | Real-time (MT207 / MT419) |
| Formaldehyde HCHO | 0.08 ppm | 1 hour | Real-time (MT419) |
| Ozone O₃ | 0.06 ppm | 8 hours | Real-time (MT419) |
| Carbon monoxide CO | 9 ppm | 8 hours | Requires lab testing |
| Bacteria | 1500 CFU/m³ | Maximum | Requires sampling |
| Fungi | 1000 CFU/m³ | Maximum (not applicable when indoor/outdoor ratio ≤ 1.3) | Requires sampling |
Values follow the Indoor Air Quality Standards issued by Taiwan’s Ministry of Environment. Applicable venues, testing and disclosure follow the Ministry’s announcements.
Which CO2 monitor should I choose?
| Model | Measures | Best for |
|---|---|---|
| MT203 / MT203L 3-in-1 | CO₂, temperature, humidity | Basic ventilation management in classrooms, meeting rooms and offices |
| MT204 / MT207 7-in-1 | CO₂, TVOC, temperature, humidity, light, pressure, PIR activity | Offices, classrooms and commercial spaces |
| MT419 9-in-1 | CO₂, PM2.5, PM10, TVOC, HCHO, O₃, temperature and humidity; Works with WELL certified | Malls, healthcare, schools and green buildings |
| MT75 LoRaWAN® gateway | Uploads data from every monitor to the Gold-Pick cloud platform | Multiple points, floors or whole buildings |
For ventilation only, the 3-in-1 MT203 is enough. To also track TVOC, PM2.5 and formaldehyde, see IAQ monitors.
Where to install and how many?
Mount where people spend time, about 1.2–1.5 m above the floor.
Keep away from AC vents, doors and windows, copiers and heat sources.
Large or partitioned spaces need monitors in each zone to find poorly ventilated areas.
Gold-Pick surveys sites across Taiwan and plans locations and quantities.
CO2 monitor FAQ
What is the CO₂ standard for indoor air?
Taiwan’s indoor air quality standard limits the 8-hour average CO₂ to 1000 ppm.
What happens when CO₂ is too high?
High CO₂ usually means poor ventilation. People feel tired, dizzy and less focused, and other pollutants may be accumulating.
Can a CO2 monitor control fresh-air or HVAC systems?
Yes. Readings can drive ventilation, either prompting staff or switching it on automatically; the integration is planned around your equipment.
Where should monitors be installed, and how many?
Install where people spend time, about 1.2–1.5 m above the floor, away from AC vents, doors, windows, copiers and heat sources. Large or partitioned spaces need one per zone.
Can I view data remotely and export reports?
Yes. Monitors upload through the MT75 LoRaWAN® gateway to the Gold-Pick cloud, where you can view live values and trends on a computer or phone and export reports.
How much does a CO2 monitor cost?
It depends on the parameters, quantity and whether you need cloud reports and displays. Call +886-2-2557-7028 or message us on LINE for a free quote.