What is IAQ, and who needs to monitor it?
We spend most of our time indoors, where poor ventilation lets CO₂, particulates, formaldehyde and VOCs build up. Venues designated under Taiwan’s Indoor Air Quality Act, such as universities, libraries, hospitals, social welfare institutions, government offices, department stores, exhibition halls and transport stations, must appoint a dedicated IAQ manager and test and publish results regularly. The designated venues follow the Ministry of Environment’s announcements.
Spot poor ventilation and pollutant build-up early.
24-hour monitoring with instant alerts.
Records support management; MT419 helps with WELL and LEED credits.
Show live air quality on an entrance display.
The nine indoor air quality standards
| Pollutant | Standard | Averaging time | Gold-Pick monitors |
|---|---|---|---|
| Carbon dioxide CO₂ | 1000 ppm | 8 hours | Real-time (all models) |
| PM2.5 | 35 μg/m³ | 24 hours | Real-time (MT419) |
| PM10 | 75 μg/m³ | 24 hours | Real-time (MT419) |
| TVOC | 0.56 ppm | 1 hour | Real-time (MT207 / MT419) |
| Formaldehyde HCHO | 0.08 ppm | 1 hour | Real-time (MT419) |
| Ozone O₃ | 0.06 ppm | 8 hours | Real-time (MT419) |
| Carbon monoxide CO | 9 ppm | 8 hours | Requires lab testing |
| Bacteria | 1500 CFU/m³ | Maximum | Requires sampling |
| Fungi | 1000 CFU/m³ | Maximum (not applicable when indoor/outdoor ratio ≤ 1.3) | Requires sampling |
Values follow the Indoor Air Quality Standards issued by Taiwan’s Ministry of Environment. Applicable venues, testing and disclosure follow the Ministry’s announcements.
IAQ monitor comparison
| Model | Measures | Best for |
|---|---|---|
| MT203 / MT203L 3-in-1 | CO₂, temperature, humidity | Basic ventilation management in classrooms, meeting rooms and offices |
| MT204 / MT207 7-in-1 | CO₂, TVOC, temperature, humidity, light, pressure, PIR activity | Offices, classrooms and commercial spaces |
| MT419 9-in-1 | CO₂, PM2.5, PM10, TVOC, HCHO, O₃, temperature and humidity; Works with WELL certified | Malls, healthcare, schools and green buildings |
| MT75 LoRaWAN® gateway | Uploads data from every monitor to the Gold-Pick cloud platform | Multiple points, floors or whole buildings |
For ventilation only, see CO2 monitors. To check against several standards, choose the 9-in-1 MT419.
Cloud platform and displays
The MT75 LoRaWAN® gateway connects 2000+ nodes for a whole building.
View live values and trends on a computer or phone and export reports.
Show live air quality in the lobby to reassure visitors.
IAQ monitor FAQ
Which venues does Taiwan’s Indoor Air Quality Act cover?
Mainly busy public places where people stay for long periods, such as universities, libraries, hospitals, social welfare institutions, government offices, department stores, exhibition halls and transport stations. Designated venues must appoint a manager and test and publish results regularly, as announced by the Ministry of Environment.
What are the nine indoor air quality standards?
Carbon dioxide, carbon monoxide, formaldehyde, TVOC, bacteria, fungi, PM10, PM2.5 and ozone. See the table on this page for values and averaging times.
Can an IAQ monitor measure all nine?
No. CO₂, PM2.5, PM10, TVOC, formaldehyde and ozone can be measured in real time with MT419. Carbon monoxide requires lab testing, and bacteria and fungi require sampling.
Which IAQ monitor should I choose?
MT203 (CO₂, temperature, humidity) for ventilation only; MT207 for offices and classrooms; the 9-in-1 MT419 for malls, healthcare, schools or checking against several standards.
Is there a monitor for WELL or LEED certification?
Yes. MT419 is Works with WELL certified and helps with indoor air quality credits in WELL and LEED.
What services does Gold-Pick provide?
On-site surveys across Taiwan, location planning, installation, training and maintenance. Pricing depends on parameters and quantity. Call +886-2-2557-7028 or message us on LINE.